Question
Download Solution PDFWhich loss has least proportion in DC machines?
Answer (Detailed Solution Below)
Detailed Solution
Download Solution PDFExplanation:
Losses in DC Machines
Definition: In DC machines (both motors and generators), losses occur due to energy dissipation in various forms. These losses directly affect the efficiency of the machine and can be broadly categorized into electrical losses, magnetic losses, and mechanical losses. Understanding the nature and proportion of these losses is crucial for machine optimization and performance improvement.
Types of Losses in DC Machines:
- Electrical Losses: These include armature copper loss and field copper loss, caused by the resistance in the windings.
- Magnetic Losses: These are associated with the magnetic field in the machine and include hysteresis and eddy current losses in the core.
- Mechanical Losses: These are due to friction and windage in the machine.
Correct Option Analysis:
The correct option is:
Option 4: Mechanical Loss
Mechanical losses in a DC machine are typically the smallest in proportion compared to the other losses. These losses consist of:
- Friction Losses: Caused by the friction between the rotating parts of the machine, such as bearings and brushes.
- Windage Losses: Due to the air resistance encountered by the rotating parts (e.g., armature and fan).
The magnitude of mechanical losses is relatively low because modern DC machines are designed with high-quality bearings and low-friction materials to minimize these losses. Additionally, advanced designs ensure that the windage losses are kept to a minimum by using streamlined structures and efficient cooling mechanisms. As a result, mechanical losses contribute the least proportion to the total losses in a DC machine.
Conclusion: Mechanical losses are the least in proportion due to advancements in design and material selection, making them significantly lower than electrical and magnetic losses.
Important Information
To further understand the analysis, let’s evaluate the other options:
Option 1: Armature Copper Loss
Armature copper loss is a significant electrical loss in DC machines. It is caused by the resistance of the armature winding and the current flowing through it. The armature copper loss can be expressed as:
PCu = Ia2 × Ra
Where:
- Ia = Armature current
- Ra = Resistance of the armature winding
Since the armature current is usually high, this loss is substantial in proportion. It is also load-dependent, meaning it increases with the load on the machine.
Option 2: Field Copper Loss
Field copper loss is another type of electrical loss, caused by the resistance of the field winding and the current flowing through it. It is given by:
Pf = If2 × Rf
Where:
- If = Field current
- Rf = Resistance of the field winding
This loss is relatively smaller than armature copper loss in proportion because the field current is typically much lower than the armature current. However, it is still larger than mechanical losses.
Option 3: Magnetic Loss
Magnetic losses, also known as core losses, occur in the iron core of the machine and consist of:
- Hysteresis Loss: Caused by the repeated magnetization and demagnetization of the core material. It depends on the frequency of magnetic reversals and the material's hysteresis coefficient.
- Eddy Current Loss: Caused by circulating currents induced in the core material due to changing magnetic fields. It depends on the square of the frequency and the thickness of the core laminations.
Magnetic losses are significant and occur even under no-load conditions. They are larger in proportion than mechanical losses but smaller compared to armature copper losses.
Option 5: Combination of Losses (Not Mentioned in Detail)
This option is not explicitly analyzed but may refer to combined losses like stray load losses or other minor losses. Such losses are generally minimal and not considered separately in most analyses.
Conclusion:
In conclusion, the proportion of different losses in a DC machine can be summarized as:
- Armature copper loss is the largest, being load-dependent and influenced by high armature current.
- Field copper loss is smaller than armature copper loss but still significant compared to mechanical losses.
- Magnetic losses are substantial under no-load conditions but smaller than armature copper losses.
- Mechanical losses are the least in proportion due to advancements in design and material selection.
Thus, the correct answer is Option 4: Mechanical Loss.
Last updated on Jul 1, 2025
-> JKSSB Junior Engineer recruitment exam date 2025 for Civil and Electrical Engineering has been rescheduled on its official website.
-> JKSSB JE exam will be conducted on 31st August (Civil), and on 24th August 2025 (Electrical).
-> JKSSB JE application form correction facility has been started. Candidates can make corrections in the JKSSB recruitment 2025 form from June 23 to 27.
-> JKSSB JE recruitment 2025 notification has been released for Civil Engineering.
-> A total of 508 vacancies has been announced for JKSSB JE Civil Engineering recruitment 2025.
-> JKSSB JE Online Application form will be activated from 18th May 2025 to 16th June 2025
-> Candidates who are preparing for the exam can access the JKSSB JE syllabus PDF from official website of JKSSB.
-> The candidates can check the JKSSB JE Previous Year Papers to understand the difficulty level of the exam.
-> Candidates also attempt the JKSSB JE Mock Test which gives you an experience of the actual exam.